Lambda Deploys 10,000-GPU Blackwell Ultra Cluster in Quebec Using Nvidia CPO Switching

DataNews Editorial Team

Image source: primary source

Lambda has deployed a 10,000-GPU Blackwell Ultra cluster at its Quebec, Canada data center using Nvidia GB300 NVL72 systems and Nvidia photonic co-packaged-optics (CPO) switches. The deployment is described by the source as one of the first implementations of Nvidia Photonics.

Highlights
  • Lambda deployed 10,000 Blackwell Ultra GPUs in Quebec using Nvidia GB300 NVL72 systems and photonic CPO switches.
  • The deployment follows a one-year Lambda evaluation of CPO against conventional pluggable silicon-photonics technology.
  • Lambda reports up to 5x better switch-package power efficiency and lower rack- and pod-level latency; these are company claims.
  • The source describes the installation as one of the first deployments of Nvidia Photonics.
  • Lambda’s stated 3 GW across 15 North American data centers is a company-wide metric, not a confirmed capacity figure for the Quebec cluster.

Lambda has deployed a scalable cluster of 10,000 Nvidia Blackwell Ultra GPUs at a data center in Quebec, Canada, using Nvidia GB300 NVL72 systems and Nvidia photonic co-packaged-optics switches.

The company said it evaluated CPO switching against conventional pluggable silicon-photonics technology for a year before deployment. The photonic switches provide 144 ports at 800 Gb/s each and use 18 removable external lasers, according to the source.

Lambda attributes several network-level benefits to the CPO architecture. It reports up to a fivefold improvement in power efficiency for the switch package itself, not for the overall cluster or facility. It also reports roughly 4% lower latency at rack level and roughly 10% lower latency at pod level. Lambda further cites up to 15x higher reliability and four times fewer lasers, although the supplied material does not specify the methodology behind the reliability measure.

For large GPU deployments, the network fabric is becoming a significant design consideration as interconnect density and link length increase. Lambda’s implementation could indicate emerging demand for more power-efficient optical interconnects in AI infrastructure, particularly where copper-based approaches become less efficient. If the claimed performance is validated, network design could carry greater weight in the operating economics of GPU data centers alongside accelerator acquisition and power availability.

The source characterizes the Quebec deployment as one of the first implementations of Nvidia Photonics. Lambda also states that it provides 3 GW of “computing power” across 15 data centers in North America, but that company-wide figure is not disclosed as IT load, electrical capacity, or another capacity measure and should not be interpreted as the power capacity of the Quebec cluster.

Why It Matters

The deployment places optical interconnect technology inside a large-scale AI cluster, where network power consumption and latency become increasingly material constraints. If Lambda’s stated results are borne out, CPO could raise the importance of network architecture in GPU data-center economics alongside accelerator procurement and power supply.